| Standardization field | Construction
|
| Technical committee | BAS/TC 37- Fire safety in buildings |
| Term (EN) | extinction area of smoke |
| Definition (EN) | product of the volume occupied by smoke (4.293) and the extinction coefficient (4.93) of the smoke
NOTE It is a measure of the amount of smoke, and the typical units are square metres (m2). |
| Term (FR) | |
| Definition (FR) | |
| Term (DE) | |
| Definition (DE) | |
| Term (BS) | površina ekstinkcije dima |
| Definition (BS) | proizvod zapremine koju zauzima dim (4.293) i koeficijenta ekstinkcije (4.93) dima
NAPOMENA Predstavlja mjeru količine dima i tipične jedinice su kvadratni metri (m2). |
| Term (HR) | |
| Definition (HR) | |
| Term (SR) | |
| Definition (SR) | |
| Date | 2016-05-13 |
| Standards | BAS EN ISO 13943:2015 |
|---|