pnBAS HD 60269-2/A1:2024

Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K


General information
Status:Project
Number of pages:16
Adoption method:Proglašavanje
Language:engleski
Edition:1.
Realization date:15.04.2024
Forseen date for next stage code:03.05.2024
Technical committee:BAS/TC 18, Power transformers, measuring relays and protective equipment
Directives:
2014/35/EU, Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits
ICS:
29.120.50, Fuses and other overcurrent protection devices

Abstract
IEC 60269-2:2013 provides supplementary requirements for fuses for use by authorized persons and are generally designed to be used in installations where the fuse-links are accessible to, and may be replaced by, authorized persons only. Fuses for use by authorized persons according to the following fuse systems also comply with the requirements of the corresponding subclauses of IEC 60269-1, unless otherwise defined in this standard. This standard is divided into fuse systems, each dealing with a specific example of standardized fuses for use by authorized persons: - Fuse system A: Fuses with fuse-links with blade contacts (NH fuse system), - Fuse system B: Fuses with striker fuse-links with blade contacts (NH fuse system), - Fuse system C: Fuse-rails (NH fuse system), - Fuse system D: Fuse-bases for busbar mounting (NH fuse system), - Fuse system E: Fuses with fuse-links for bolted connections (BS bolted fuse system), - Fuse system F: Fuses with fuse-links having cylindrical contact caps (NF cylindrical fuse system), - Fuse system G: Fuses with fuse-links with offset blade contacts (BS clip-in fuse system), - Fuse system H: Fuses with fuse-links having 'gD' and 'gN' characteristic (class J and class time delay and non time delay fuse types), - Fuse system I: gU fuse-links with wedge tightening contacts, - Fuse system J: Fuses with fuse-links having 'gD class CC' and 'gN class CC' characteristics (class CC time delay and non-time delay fuse types), - Fuse system K: gK fuse-links with blade for bolted connections - High fuse-link ratings from 1 250 A up to 4 800 A (master fuse-links). This fifth edition of IEC 60269-2 cancels and replaces the fourth edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: 1. fuse systems A and B: modified values for the power dissipation of NH aM fuse-links; 2. fuse systems A and B: introduction of dimension r for NH fuse-links; 3. addition of new fuse system K: gK fuse-links with contacts for bolted connections. Key Words: fuse systems A to K, requirements for fuses

Lifecycle
...

Original document and degree of correspondence
HD 60269-2:2013/A1:2022, identical
IEC 60269-2:2013/AMD1:2016, identical

Work material

Only members of the technical committee have access to work material. If you are a members of this technical committee you need to login to view the documents. Login